When installing or repairing the air conditioner and the
connecting line is not long enough, the entire connecting line
shall be replaced with the connecting line of the original
specification; extension is not allowed.
Use new connection pipe, unless re-flaring the pipe.
_
Requirements For lnstallation Position
• Avoid places of inflammable or explosive gas leakage or where
there are strongly aggressive gases.
• Avoid places subject to strong artificial electric/magnetic fields.
• Avoid places subJect to noise and resonance.
• Avoid severe natural conditions (e.g. heavy lampblack, strong
sandy wind, direct sunshine or h1gli temperature heat sources).
• Avoid places within the reach of cnildren.
• Shorten the connection between the indoor and outdoor units.
• Select where it is easy to perform service and repair and
where the ventilation good.
• The outdoor unit shalrnot be installed in any way that could
occupy an aisle, stairway, exit, tire escape, catwalk or any other
public area.
• The outdoor unit shall be installed as far as possible from the
doors and windows of the neighbors as well as the green plants.
Check nameRlate of outdoor unit to make sure whether the
refrigerant is R32.
Check the floor space of the room. The space shall not be less
than usable space(Sm
be installed at a well-ventilated place.
Check the surrounding environment of installation site: R32 shall
not be installed in the enclosed reserved space of a building.
When using electric drill to make holes in the wall, check first
whether there is pre-buried pipeline for water, electricity and gas.
lt is suggested to use the reserved hole in the roof of tfle walr
�---
_
Requirements of the mounting structure
• The mounting rack must meet the relevant national or industrial
standards in terms of strength with welding and connection
a reas rustproofed.
• The mounting rack and its load carry surface shall be able to
withstand 4 times or above the weight of the unit, or 200kg,
whichever is heavier.
www.infiniton.es
lnstallation environment inspection
2
in the specification.The outdoor unit shall
)
©@
Notices for installati