4
STOVE OPERATION
4.1 STARTING THE STOVE
Before every ignition, be sure that burning pot is completely empty and properly positioned in its
seat.
To start the stove hold the
The flame icon will start flashing during the ignition stage until remaining on steady when the stove has started.
Automatic stove ignition: the stove comes with an automatic device that starts the pellet stove with-
out using other traditional fire lighters.
Avoid lighting the flame manually if the stove's automatic ignition system is not working correctly.
When the stove is started the first time, unpleasant odours or smoke may be generated, caused by
evaporation or drying of certain materials used. This phenomenon will gradually disappear.
The room should be well ventilated when starting the stove the first few times.
4.2 MODIFYING THE PARAMETERS
The stove operating parameters can be modified as described.
The values set will be retained until next modified, even when the stove is switched off or unplugged
from the power supply.
4.3 SWITCHING OFF
To switch the stove off hold the
To start the stove again it's recommended to wait for the stove to cool down completely.
The stove should only be switched off following the procedure described above. Never switch the
stove off by unplugging it from the power supply.
4.4 OPERATION WITH ROOM THERMOSTAT
When the stove is controlled by an external thermostat (or timer thermostat), the installer must have set configuration 1.
In this configuration the stove switches off when reaching the external thermostat setting or alternatively modulates output
(that is, the stove attempts to maintain the desired temperature while minimising fuel consumption) when reaching the
set water temperature.
The stove switches on again automatically when the temperature falls below the value set on the external thermostat
(circuit closed).
On first ignition, or if the stove has been switched off manually (
started directly from the control panel.
The stove will go off automatically even in the case the water temperature keeps growing notwithstanding the modulation
mode. In this case the stove will ignite only if the difference between the selected and actual temperature is over 20°C.
Therefore, if you choose this configuration, we suggest that you select a high water temperature (e.g.. 70°C).
4.5 OPERATION WITH ROOM PROBE ON THE BOILER
The boiler can be switched on/off manually or in programmed mode.
In this type of configuration, the boiler modulates output according to the room temperature read by the probe on the
boiler (that is, the boiler attempts to maintain the desired temperature while minimising fuel consumption).
If the user has enabled the "Eco-mode" function under submenu [7] of the setup menu
modulating its output, switches off when reaching the set temperature, and switches on again when the room
temperature falls below the delta set in submenu [7] of the setup menu
The desired room temperature can be set in temperature menu
Submenu [
of the setup menu
6]
the heating system in question should be suggested by the heating system installer).
004778911 - 26/01/2022
ITALIANO
ENGLISH
button for several seconds.
button for a few seconds; the flame icon will switch off.
can be used to set the desired water outlet temperature (the best temperature for
DEUTSCH
FRANÇAIS
button), the stove needs to be
.
.
ESPAÑOL
, the boiler rather than
23