10. Accessories
GB
Half shells
16
Solder iron
Internal guides
1
WIKA operating instructions model 54, Twin-Temp
4. Solder each wire to the
corresponding contact
5. Bend cable shield outwards,
assemble half shells
6. Slide the EMI ring and collet
against the half shells so that the
shield is clamped between EMI
ring and half shells
7. Put the assembled cable into the
plug-housing, considering the
internal guides.
If needed, secure thread (A) with
locking glue
8. Screw back nut on the plug, hold
against flat (1) and fasten with an
open-ended spanner.
Tightening torque: 0.6 Nm