7. PROBLEM SOLVING
PROBLEMS
- The equipment doesn´t turn
on.
- The machine starts, but when
the product is placed on the
equipment, it stops or turns
slowly.
- The cut product is stuck inside
the equipment.
- Burning or smoke smell.
- Irregular cut.
- Damaged Cable.
- Abnormal noises.
8
CHART 07
CAUSES
- Incorrect starting procedure;
- Thermal protector working;
- The Disc Housing Lid is open;
- Problem with Internal or External Electrical
circuit;
- Lack of electrical energy.
- The belt is sliding.
- The safety device of the Lid is not working;
- Problems with the Electrical Motor.
- Lack of expelling plate.
- Outlet Nozzle is blocked.
- Problem with Internal or External Electrical
circuit.
- The Blades are not cutting anymore.
- Problems in the shipping.
- Problems with the bearings.
SOLUCTIONS
- Read the item 3.1 -
Starting the machine;
- Wait for some minutes and start again;
- Close the Lid;
- Call the Authorized Assistance;
- Check if there´s electric power.
- Adjust the belts tension;
- Call the Authorized Assistance;
- Call the Authorized Assistance.
- Place the Expelling Plate.
- Unblock the Nozzle.
- Call the Authorized Assistance.
- Sharpen the Blades.
- Call the Authorized Assistance.
- Call the Authorized Assistance.