3.3. Specifications
Technical data
Air
Min/max air pressure.
Compressed air consumption.
Air quick connector
General
Product flowrate
Sound level ISO 11202
Weight
4. Overview and Use
Drainspexx is an equipment allowing to easily apply a fog of a disinfecting biocide to the surface of pre-cleaned
drain pipes / channels. The biocide can be left on the surfaces without rinsing.
In effect it leads to a reduction of germs at these surfaces. Regularly applied, it is giving additional safety
against microbiological contaminations in the production area, provided the standard treatment for drain lines is
applied also.
A layout of the equipment can be found on page 27.
5. System Safety
The Drainspexx unit must only be used for professional use by a trained operator.
•
The only biocides allowed are listed below:
Biocides
Kenolox 10
Aseptanios AF 310
Availability may depend on government approvals in the individual country. Do NOT mix 2 different biocides.
If any other biocides are used serious injuries cannot be excluded. The use is restricted to closed drain pipe
systems. Apply to a single pipe system, drain by drain, one drain at a time. The manual must be followed strictly.
• The air pressure for the unit is set to 6 bar. It must not be changed.
Safety
Wear appropriate PPE
•
Working boots class S2.
•
Safety glasses.
•
Gloves and suitable clothing.
Wear glasses when using
the unit.
Wear gloves and suitable
clothing when using the
unit.
Unit
MPa (bar)
NL/min
-
ml/min
dB
Kg
0,7-1,0 (7-10)
500
380
Below 70
22.4
11