8. Maintenance & Trouble shooting
Service may only be carried out by authorized and qualified personnel.

8.1. Handle/adaptor

It is recommended to lubricate the o-ring of the handle regularly (approx. once a week) with waterproof grease
to prevent leaks and damage of packings.

8.2. Cleaning of the unit

We recommend cleaning the unit after each use (weekly).

8.3. Trouble shooting and Remedy

Fault
No suction of biocides
Not able to reach 6 bar on
pressure gage
16
Cause
• No air supply
• Faulty nozzle or drain adapter
The air supply is insuf-
ficient
Remedy
• Check air supply
• Check air supply hose
• Change the drain adaptor
• Clean the drain adaptor and nozzle for
debris
• Check the nozzle for damages
• Check the o-ring at the nozzle, replace if
damaged
• Make sure that the nozzle and the drain
adapter is screwed tight together.
• Remove any additional air supply hoses
• Check air supply hose for debris
• Ensure air hoses have no leaks
• Make sure the air supply meets the
requirement listed in the specification