iTEMP TMT182B
Endress+Hauser
Número de
Texto corto
diagnóstico
043
Short circuit
047
Sensor limit reached
Diagnóstico de la electrónica
145
Compensation
reference point
201
Electronics faulty
221
Reference sensor
defective
Diagnóstico de la configuración
401
Factory reset active
402
Initialization active
402
Initialization active
410
Data transfer failed
411
Up-/download active
435
Linearization faulty
485
Process variable
simulation active
491
Output simulation
495
Diagnostic event
simulation active
531
Factory adjustment
missing
537
Configuration
537
Configuration
582
Sensor diagnostics TC
deactivated
Diagnóstico del proceso
801
Supply voltage too low Increase supply voltage
825
Operating
temperature
844
Process value out of
specification
Diagnósticos y localización y resolución de fallos
Remedio
1. Check electrical connection
2. Check sensor
3. Replace sensor or cable
1. Check sensor
2. Check process conditions
1. Check terminal
temperature
2. Check external reference
point
1. Restart device
2. Replace electronics
Replace device
Factory reset in progress,
please wait
Initialization in progress,
please wait
1. Check connection
2. Repeat data transfer
Up-/download in progress,
please wait
Check linearization
Deactivate simulation
Deactivate simulation
Deactivate simulation
1. Contact service
organization
2. Replace device
1. Check device configuration
2. Up- and download new
configuration
Check current output
configuration
Switch on diagnostics for
thermocouple measurement
1. Check ambient
temperature
2. Check process temperature
1. Check process value
2. Check application
3. Check sensor
Señal de
Comportamiento de
estado
diagnóstico
[Ex-fábrica]
[Ex-fábrica]
F
Alarm
S
Warning
F
Alarm
F
Alarm
M
Alarm
C
Warning
C
Warning
C
Warning
F
Alarm
C
Warning
F
Alarm
C
Warning
C
Warning
C
Warning
F
Alarm
F
Alarm
F
Alarm
C
Warning
S
Alarm
S
Warning
S
Warning