Infiniton SPLIT-3630ES Manual De Usuario página 61

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OUTDOOR UNIT INSTALLATION
Step5:
Connecting Refrigerant Pipe
5.2 Unscrews the valve cover, grasp and press it down gently to take it down(if the valve cover is
applicable).
5.3 Remove the protective caps from the end of valves.
5.4
Take off the plastic cover in the pipe ports and
the connecting pipe and make ensure the port is clean.
5.5 After align the center, rotate the flare nut of the connecting pipe to tighten the nut as tightly as
possible by hand.
5.6 Use a spanner hold the body of the valve and use a torque wrench to tighten the flare nut
according to the torque values in the torque requirements table.
(Refer to the torque requirements table on section INSTALLATION PRECAUTIONS)
connection pipes
Take down the valve cover
flare nuts
check whether there is any sundry on the port of
22

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Split-3908tp

Tabla de contenido