Prepare The Unit - Broan Powerpack Inserts PM400SSV Instrucciones De Instalación, Uso Y Cuidado

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PREPARE THE UNIT

A
LL INSTALLATIONS
NOTE: Since this manual covers 2 different unit models, some
details in the following illustrations may slightly differ
from your unit.
1. If present, remove all protective polyfilm from the unit and/
or parts.
2. Remove the grease filter by pushing down on latch tab and
tilting the filter downward (FIG. 14). Set aside the filter.
3. Disassemble the electrical compartment cover (grey part
in FIG. 15) from inside the unit by removing its retaining
screw. Remove the parts bag behind the cover. Set aside
the parts bag and the cover along with its screw.
4. Punch out one of the two knock-out holes. Install an
appropriate 7/8" diameter strain relief (not included, grey
part in FIG. 16).
NOTE: The HCK44 cord connection kit (optional) can
be used instead of the house power cable. Refer to the
instruction packed with the HCK44 cord connection kit.
H
ORIZONTAL EXHAUST INSTALLATION ONLY
5. Remove and discard the screw circled in FIG. 17.
NOTE: This screw might be present or not.
6. Unplug the blower cable from its connector on faceplate.
Disassemble the faceplate from the unit by removing its
4 retaining screws (two per side, circled in FIG. 18) . Set
aside the faceplate along with its screws.
10
10-0548
FIG. 14
SCREW
FIG. 15
FIG. 16
FIG. 17
FIG. 18