FALMEC Design Mira Top FFMIR16W5FS-R Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, the air passes through the charcoal filters to be
purified and recycled in the environment.
Ensure that the active carbon filters are assembled into the
hood, if not, install them as indicated in the assembly instruc-
tions.
In this version the check valve must not be assembled: remove it if it is
on the air outlet fitting of the motor.
ASSEMBLY INSTRUCTIONS
only intended for qualified personnel
The hood can be installed in various configurations.
The generic assembly steps apply to all installations; for each case,
follow the specific steps provided for the required installation.
SRS SYSTEM SETTING
The SRS system reduces the maximum air flow rate that can be set
in the hood.
This makes the hood compliant with local building regulations.
MAX SPEED LEVEL 3
1
Apply the label
Code
Serial n.
Fig. 1: Set maximum speed 3:
Press keys
+
for 5 seconds
All keys flash.
Within 5 seconds, press and hold the
If all the keys light up and are steady, the setting procedure
has been successful.
Max Speed
3
Selection
key for 5 seconds
MAX SPEED LEVEL 2
2
Apply the label
Code
Serial n.
Fig. 2: Set maximum speed 2:
Press keys
+
for 5 seconds. All keys flash.
Within 5 seconds, press and hold the
If all the keys light up and are steady, the setting procedure
has been successful.
9
Max Speed
2
Selection
key for 5 seconds

Publicidad

Tabla de contenido
loading