4.7.
Remove the packaging and the protective plastic.
4.8.
Remove the screws or bolts that fasten the stove to the pallet and remove it.
4.9.
If our model has a plastic protection, it must be removed before starting it.
4.10. Remove the protection of the exhaust gas fan and the convector in the case of ductable stoves.
To remove the gas output cover in models with option for top output, it is necessary to access the inside of
the stove to remove the cover nuts.
Airtight installation for Marsella model:
No DIFLUX: Remove the protection from the extractor () and from the air inlet pipe ().Drawing 5.
DIFLUX: Remove the top cover ().
Drawing 3
MATERIAL
It will be made of a material
resistant to the aggressive action
of the combustion products, to
condensation and to constant
temperatures of 300 °C. The
material will comply with the
local
legislation
for
application.
Aluminum, galvanized or iron
pipe.
Insulated double wall pipe.
Elbow Ø80 X 90°
T with outlet.
Clamp union.
Pipe anchors.
UNPACKING THE STOVE.
MATERIAL REQUIRED FOR INSALLATION.
COMPLIANCE
OBLIGATORY
its
PROHIBITED
OBLIGATORY
RECOMMENDABLE
OBLIGATORY
OBLIGATORY
OBLIGATORY
OBLIGATORY
Drawing 4
• ALL.
• ALL.
• Proximity to flammable materials.
• When crossing a forge or partition.
• Outdoor or brick-built chimney installation.
• Insert stoves. See figure 7.
• Relative ambient humidity ≥ 60%.
• Installation in a public facility.
• Potentially accessible to children or people with
mental, physical or sensory disabilities.
• Tokio and Bolonia models. Exhaust gas outlet
with rear connection
• ALL.
• Install the exhaust spiral and gas outlet pipes,
thereby preventing anyone from disassembling
or moving the stove or pipe without tools.
• Install the pipe, thereby preventing anyone from
48