Windbreak.
Stainless steel hose clamp.
T of 90° with outlet.
Insulator.
Wooden ground.
Non flammable floor protection.
*Distance equal to or less than 2 metres.
4.29. When fitting stoves in brickwork chimneys a perfect seal between the flexible and the rigid pipe must be
achieved. Similarly, the insulation to be placed at the contact areas between the pipe and possibly
inflammable zones must be taken into account. The tube end may be left inside the chimney itself, taking
into account its opening.
Once installation is complete, we must seal the chimney from the inside of the house.
Stainless steel hose clamp.
T of 90° with outlet.
Wooden ground.
Non flammable floor protection.
Isolated stainless steel flexible tube.
Rigid flexible pole adapter.
Minimum 200mm.
It must exceed roof height by 1 metre.
If the tube over 8 m in length, the next larger
size will be used.
4.30. Installing a fitted stove in a brickwork chimney can be done using flexible piping in its entirety, as indicated in
drawing 16. We must take special care when sealing the chimney and gas venting to avoid gas blowing back
during storms.
54
Drawing 14
Drawing 15