Ecoforest only guarantees the correct operation of the stove if the dimensions and the position of the
ventilation grids are respected.
If the installation does not allow to respect the location of the ventilation grids, the standard measures of
built-in installations must be taken into account (drawing 8), in order to avoid excess temperature on
electronic board and temperature probe. It is recommended to have one of the ventilation grilles at the CPU
height to facilitate its cooling and revision.
A
Lateral wall 'flammable.
A
Lateral wall 'not flammable.
B
Back of the stove.
C
Open door and stove depth.
D
Cover.

Ventilation grill. OBLIGATORY.
Isolated output gas pipe within the

socket. OBLIGATORY
PLACING LEGS ON THE CÓRDOBA GLASS, GRANADA, TEIDE AND CÓRDOBA MODELS (OPTIONAL).
4.14. Join the 4 legs to form a rectangle with side and front strengtheners as indicated in drawing 9.
Open the stove guides in such a way that we can access the fixing points for the legs at the base of the stove.
The assembly order for the stove resting above its legs will depend on the installer's needs, being able to fix
the legs into place and perform the base assembly later; or either assemble the entire stove and legs and
later position this and fix the legs to the floor. It is compulsory to screw the legs to the floor.
 
B
B
C
C
C
C
See dimensions
Effective area
B
50
Drawing 7
≥ 650 mm
≥ 420 mm
≥ 80 mm
≥ 500 mm
2
456 cm
x 2
Ø80mm.
50
B-B SECTION
C-C SECTION
50
50
Drawing 8