3.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to
select
the microphone type EL (electret) or dy dynamic.
4.
Short press the EMG key (5) to validate. a) Return to the point 1 to set an-
other menu or b) Short press the F key (9) to
disappears from the display.
5.
If no key is pressed, the unit
exits
from the display.
Microphone type default is EL (electret).
10) SWR CALIBRATION
adjust
This function allows you to
Press F key (9).
is displayed.
Long press F key (9) to
enter
the MENU.
1.
Turn the rotary CH knob (6) or use UP/DN buttons (13) on the microphone
to
select
the
menu.
2.
Press the EMG key (5) to confirm. The radio automatically switches to
mode without pressing the PTT switch (12) and calibration begins. Calibra-
tion time is 5 minutes maximum. A countdown is done in the display.
3.
Adjust the antenna.
-
The beep* is continuous when the SWR value is 1. 0 . The space between the
beeps becomes larger and larger as the SWR value moves away from1. 0 .
The volume of the beep is adjustable with the VOL button (1).
-
-
The display shows the SWR value, for example 2. 5 .
4.
Press the PTT switch (12) to
exit
*Check that the beep volume is set to a suitable level.
See ADJUSTMENT OF SWR page 40.
11) NRC SET
The NRC filter can be set independently in transmission ( ) as in reception
( ).
Press F key (9).
is displayed.
Long press F key (9) to
enter
the MENU.
1.
Turn the rotary CH knob (6) or use UP/DN buttons (13) on the microphone to
select
the
menu. The last parameter used and its value appears
on the display.
2.
Press the EMG key (5) to confirm. The parameter blinks,
3.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
select
to
(recepetion) or
(transmission).
4.
Press the EMG key (5) to confirm. The value of the filter blinks.
5.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
to
change
the value from 0 to 5.
validate
and
exit
the MENU.
MENU after 10 seconds.
disappears
the SWR by beeping.
the SWR CALIBRATION.
or
.
6.
Short press the EMG key (5) to validate. a) Return to the point 1 to set an-
other menu or b) Short press the F key (9) to
disappears from the display.
The default value are 0 (transmision) and 0 (reception)
See the § NRC page 43 to
12) VOLUME ACCESSORY
This function allows you to control the volume of the unit and an accessory
plugged on the 6-pin plug (accessory available soon).
Press F key (9).
is displayed.
Long press F key (9) to
1.
Turn the rotary CH knob (6) or use UP/DN buttons (13) on the microphone
to
select
the
2.
Press EMG key (5) to
validate.
3.
Turn the rotary CH knob (6) or use the UP/DN buttons (13) on the microphone
TX
select
to
0,1 or 2.
4.
Short press the EMG key (5) to validate. a) Return to the point 1 to set an-
other menu or b) Short press the F key (9) to
disappears from the display.
5.
If no key is pressed, the unit
from the display.
0 - the volume knob (1) affects the internal speaker volume.
1 - the volume knob (1) affect the accessory volume
2 - the volume knob (1) affects both the internal speaker and accessory volume.
Default accessory volume is 0.
13) CODE SET
For simplicity, in this manual we will speak of CTCSS/DCS code to indicate
both a CTCSS tone and a DCS code, of GENRE to indicate the kind of code
(CTCSS, DCS or OFF = no code). TYPE indicates whether this is a TX transmis-
sion or an RX reception and MODE specifies the operating mode, Identical
Id or different DF. See § CTCSS/DCS page 42.
This menu allows you to configure the operating mode of the CTCSS/DCS
function and to store the CTCSS/DCS codes.
2 operating modes:
-
I d means that the code used will be identical for transmission (TX) and for
reception (RX).
-
DF means that the user can use one code (or OFF = no code) for transmis-
sion (TX) and another (or OFF = no code) for reception (RX).
48
validate
and
activate/deactivate
the function.
enter
the MENU.
menu.
The current value blinks on the display.
validate
and
exits
MENU after 10 seconds.
exit
the MENU.
exit
the MENU.
disappears