1
Abb. 10: Housing lock with Aluminium housing
1
Single chamber housing
2
Double chamber housing
3
Housing
4
Housing lock
1
Abb. 11: Housing lock with precision-cast stainless
steel housing
1
Single chamber housing
2
Double chamber housing
3
Housing
4
Housing lock
Abb. 12: Housing lock with electropolished stainless
steel housing
1
Housing
2
Housing lock
3
Mounting
3.1
Mounting preparations
Tool
Required tools:
•
Hexagon socket wrench (size 4)
3.2
Installation procedure
Proceed as follows:
1. Loosen the hexagon screws and dismantle
the clamp collars
Polarisation lock VEGAPULS 64, 69 • 4 ... 20 mA
3
4
2
3
4
2
1
2
2. For sensors with plastic horn antenna and
40 mm clamping diameter, use a adjusting
ring.
3. Assemble the clamp collars on the housing
- process fitting junction
Abb. 13: Mounting the housing lock
1
Housing
2
Clamp collars
3
Adjusting ring
4
Screws
4. Tighten hexagon screws evenly in two or
three passes. Tightening torque, see chap-
ter "Technical data".
5. Check if the housing is securely tightened
against the process fitting
3 Mounting
1
2
3
4
9