4.2.3.2 HOW TO PROGRAM THE INTERCOM FUNCTION
Example:
key = general intercom to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
combination in which the intercom function (INT) is listed for the keys you wish to program.
2.2 Addressing:
for internal intercom set S1 DIP switches with the same user code of the internal unit.
for general intercom to another user code set S1 DIP switches with the desired
address see page
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000
Restore the user code setting on S1
4.2.3.3 HOW TO PROGRAM THE PAGING FUNCTION
Example:
key = general paging to user code 3
√
Take note of the S1 setting and restore it when programming is complete
1
Enter programming mode
Set S2 DIP switch 5-6 to the combination 01
» the Privacy LED flashes
2
2.1 Choose the function: refer to the
combination in which the paging function (PAG) is listed for the keys you wish to program.
2.2 Addressing:
for internal paging set S1 DIP switches with the same user code of the internal unit.
for general paging to another user code set S1 DIP switches with the desired address
(see page
27 "TAB. A" ).
3
Select the key to be associated with the function
Press and release the key to be associated with the function
» the lock-release LED lights up
» a confirmation tone will sound.
4
Exit programming mode
To exit programming mode, set S2 DIP switches 5-6 to the combination 00
» the Privacy LED switches off
5
When programming is complete,
Set S2 DIP switches 1-2-3-4 to the combination 1111 (PROG setting). In this DIP switch
setting, the keys control the programmed functions; the NON-programmed keys control
functions referred to on line 0000
Restore the user code setting on S1.
"Preset function"
table and select a S2 DIP switches
27 "TAB. A" .
(21 "4.2.1 Preset function"
"Preset function"
table and select a S2 DIP switches
("Preset
function"table).
table)
ON
1 2 3 4
5
6 7
8
Example: 0100
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
Example: 0100
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
ON
1 2 3 4
5
6 7
8
23