USER OPTIONS
IMPORTANT:
This machine contains a refrigerant that must be allowed to settle after being transported. Leave
the machine on a flat surface for at least 12 hours after purchasing it or after any movement,
during which the machine has been turned over. Leave at least 20 cm on each side of the
machine to allow free air circulation. Make sure the ventilation slots are free and unobstructed.
A flow of hot air that escapes from the vents is the normal result of efficient refrigeration.
A) Use with a fixed bowl
Insert the mixing blade for a fixed bowl
(B)
Tighten the fixing knob (C).
Insert the protection ring (M). Fig.01 on
pag. 02
The machine is ready for use
B) Use with a removable bowl
Pour about 1 or 2 measuring cups (H) of
a salt and water solution (20 g salt and
80 g water) into the fixed bowl or of a
spirit with an ABV higher than 40° or of
food-grade alcohol.
Fully insert the removable bowl (G) into
the fixed bowl and press firmly
Lift it up and CHECK THAT THE
EXTERNAL WALL OF THE
REMOVABLE BOWL IS ALL WET,
otherwise the machine will not cool
properly.
Insert the mixing blade for a removable
bowl (F)
Tighten the fixing knob (C)
The machine is ready for use
ATTENTION!:
When using a saline solution, once you have finished using the machine, thoroughly wash and
dry both the fixed and removable bowls to prevent corrosion. Do not leave the saline solution
inside the bowl!
18
ENGLISH