Descargar Imprimir esta página

MACHEREY-NAGEL NANOCOLOR VIS II Guía Rápida página 14

Ocultar thumbs Ver también para NANOCOLOR VIS II:

Publicidad

Idiomas disponibles

Idiomas disponibles

Extinktion
UV/VIS II
Die gewünschte Wellenlänge der Liste hinzufügen
560 nm
560 nm
Hinzufügen
Agregar
720 nm
720 nm
Entfernen
Quitar
Limpiar
Leeren
Fig. 11: Absorbance
Round cuvette tests
NANOCOLOR
round cuvette tests can be accessed in the device in various ways. All cuvettes
®
are equipped with a barcode. When the start screen or a measurement menu is displayed, the
cuvette can be inserted and the barcode is read fully automatically. The corresponding cuvette
test is called up in the device and the measurement is automatically started (in the case of round
cuvette tests which must be measured against a zero solution, no automatic measurement is
performed). After the measurement is completed, the result is displayed in the measurement
window. Various sample information can be entered using
field. Pulling out the cuvette or exiting the measurement menu via the remaining icons in the
task bar ends the measurement procedure and saves the result in the measurement value
memory of the device.
UV/VIS II
0443 Härte Ca / Mg
49 mg/L Mg
540 nm
86 mg/L Ca
> 20.0 °d (23.4)
0.567 E
0010
Probenehmer
Probeort
Kommentar
Fig. 12: Result
The first time a method is called up, it is automatically called up in submethod 1. The
submethod (chemical form) can be switched after the measurement by clicking on the
"submethod" entry using the
Quickstart Guide NANOCOLOR
14
Open Mode, 01.03.2016, 10:57
OK
OK
Open Mode, 01.03.2016, 10:57
IQK
86 mg/L Ca
Null
Messen
icon.
+
After confirming with
window is called up. A request for the zero
solution appears. After inserting the cuvette, the
measurement procedure is started by pressing
. After the measurement of the zero solution
is completed, a request to insert the sample
solution appears. After inserting the cuvette, the
measurement procedure is started by pressing
. After the measurement is completed,
the measurement values are displayed in the
measurement window.
In
addition
to
measurement menu of the cuvette tests can also
be called up by selecting the corresponding test
from a list with round cuvette tests
entering the test number
In the case of the latter two options, no automatic
measurement of the result takes place upon
insertion of the cuvette. The measurement is
performed by pressing
NOTICE
/
II / VIS II V 2.00/09‑2022
® UV
VIS
the measurement
and the icons below the result
barcode
recognition,
.
1
2
3
4
5
6
7
8
9
.
the
or by

Publicidad

loading

Este manual también es adecuado para:

Nanocolor uv/vis ii