Remove the electric cover of the outdoor unit. If there is no cover on the outdoor unit, take
o the bolts from the maintenance board and remove the protection board.
3. Connect the u-lugs to the terminals Match the wire colors/labels with the labels on
the terminal block, and rmly screw the u-lug of each wire to its corresponding terminal.
4. Clamp down the cable with designated cable clamp.
5. Insulate unused wires with electrical tape. Keep them away from any electrical or metal parts.
6. Reinstall the cover of the electric control box.
Harmonic declaration
"The equipment
ZDAA-4090-09M25
power Ssc is greater than or equal to 4787737.5 at the interface point between the user's supply and
the public system. It is the responsibility of the installer or user of the equipment to ensure, by
consultation with the distribution network operator if necessary, that the equipment is con-nected
only to a supply with a short-circuit power Ssc greater than or equal to 4787737.5."
"The equipment
ZDAA-5130-09M25
power Ssc is greater than or equal to 3190042.5 at the interface point between the user's supply and
the public system. It is the responsibility of the installer or user of the equipment to ensure, by
consultation with the distribution network operator if necessary, that the equipment is con-nected
only to a supply with a short-circuit power Ssc greater than or equal to 3190042.5."
Wiring Figure
CAUTION
Connect the connective cables to the terminals, as identi ed, with their matching numbers
on the terminal block of the indoor and outdoor units. For example, Terminal L1(A) of the
outdoor unit must connect with terminal L1/1 on the indoor unit. The outdoor unit can
match di erent types of indoor unit, the numbers on the terminal block of the indoor unit
may be slightly di erent. Please pay special attention while connecting the wire.
Cover
Screw
complies with IEC 61000-3-12 provided that the shortcircuit
complies with IEC 61000-3-12 provided that the shortcircuit
or
or