NOTE: For quick-connector models, please refer to <<Owner's Manual & Installation Manual >>
packed with the indoor unit.
NOTE: Refer to the following gures if end-users wish to perform their own wiring.
Run the main power cord through the lower line-outlet of the cord clamp.
---- This symbol indicates eld wiring.
ZDAA-2040-09M25 and ZDAA-2050-09M25:
S(2) S(A) N(A) L(A)
N
S
(1) S(B) N(B) L(B) L
POWER
SUPPLY
TO A
TO B
Model
A
NOTE:Use the magnetic ring ( not supplied, optional part) to hitch the connective cable of
indoorand outdoor units after installation.One magnetic ring is used for one cable.
ZDAA-3080-09M25:
or
or
To indoor
To indoor
unit A
unit B
Model A
S(2) S(A) N(A) L(A)
N
S
(1) S(B) N(B) L(B) L
W
POWER
W
SUPPLY
TO A
TO B
Model B
L(C) N(C) S(C)
To indoor
unit C