5. Store the device in a frost-protected place.
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
Fault
Pump is running, but not
delivering
The pump does not start
up, or stops suddenly
during operation
The pump capacity drops
or is too low
Mains voltage
Power frequency
Nominal power
Maximum flow rate
Suction height (max.)
Pressure (max.)
Delivery height (max.)
Delivery temperature (max.)
Particle size (max.) of permissible feed fluids mm
Pump type
Sound pressure level L
pA
Guaranteed sound power level L
Dimensions and weights
Weight (without accessories)
Note
Reason for exception according to regulation (EU)
Troubleshooting guide
Cause
Air is in the pump.
Dirt particles block the suction area.
The suction hose or the connection
adapter is not correctly screwed in.
The pre-filter is clogged.
The power supply is disconnected.
The suction area is clogged.
The delivery rate of the pump depends
on the delivery head and the connected
periphery.
The cross-section on the pressure side is
narrowed, e.g. due to the valve/ball tap
not being fully open.
The hose is kinked on the pressure side. 1. Eliminate the kink points in the hose.
The pre-filter is clogged.
Specifications
V
Hz
W
l/h
m
MPa (bar) 0,36 (3,6)
m
°C
dB(A)
dB(A)
WA
kg
Special accessories
You will find the possible special accessories on the last
page of these operating instructions.
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
Rectification
1. Check for correct startup (see chapter
Preparation and Operation).
1. Pull the mains plug out of the socket.
2. Clean the suction area.
1. Check that the seals are fitted correctly.
2. Manually tighten the suction hose and con-
nection adapter.
1. Clean the pre-filter.
1. Check the fuses and the electrical connec-
tions.
1. Pull the mains plug out of the socket.
2. Clean the suction area.
1. Observe the max. delivery head (see chap-
ter Specifications), select a different hose
diameter or a different hose length if nec-
essary.
1. Open the valve/ball tap completely.
1. Clean the pre-filter.
BP 4.500
BP 5.000
Garden
Garden
BP 4.500
BP 5.000
Garden Set
Garden Set
Plus
Plus
230-240
230-240
50
50
550
650
4500
5000
8
8
0,40 (4,0)
35
40
35,0
35,0
1
1
Jet
Jet
56
58
71
73
6,4
7,0
2019/1781 Annex I Section 2 (12): (j)
Subject to technical modifications!
English
BP 6.000
BP 7.000
Garden
Garden
BP 6.000
Garden Set
Plus
230-240
230-240
50
50
1000
1100
6000
7000
8
8
0,45 (4,5)
0,5 (5,0)
45
50
35,0
35,0
1
1
Jet
Jet
69
68
84
83
9,7
10,0
11