Illustration A
Cap, 2-way connection adapter
1
2-way connection adapter for pumps G 1 (not in-
2
cluded with BP 4.500 Garden)
Connection adapter for pumps G 1 (included twice
3
with BP 4.500 Garden)
Sealing plug
4
Connection G 1 (33.3 mm) suction line (inlet)
5
Filling nozzle with cap
6
Connection G 1 (33.3 mm) pressure line (outlet)
7
ON/OFF switch
8
Water drain valve
9
**Tap connection G 1
10
**Coupling with Aqua Stop
11
**Coupling
12
**Syringe
13
*Suction hose set incl. 3.5 m ready-to-connect, vac-
14
uum-proof spiral hose with suction filter and back-
flow stop
**Garden hose 1/2" 20 m
15
Power supply cable with plug
16
* Only accessories included with Set and Set Plus.
** Only accessories included with Set Plus.
Startup
We recommend using only original Kärcher suction hos-
es, filter components and hose connections. Using
components from other manufacturers can lead to mal-
functions when sucking the feed fluid, especially when
using bayonet connection systems.
Before initial startup
Preparation
● Remove the sealing plug.
● Screw the connection adapter into the suction con-
nection of the pump (inlet). Manually tighten.
● Connect a vacuum-tight suction hose
Illustration B
Note
If the water is dirty, we recommend fitting a pre-filter
(see Special accessories) between the check valve and
the suction hose.
Illustration C
Note
To shorten the re-suction time, use a suction hose with
backflow stop. This prevents the suction hose from
emptying after use (see Special accessories).
● Screw the connection adapter into the pressure con-
nection of the pump (outlet). Manually tighten.
Illustration D
● Open the filling nozzle cap.
Illustration E
● Fill the pump with water until it overflows.
Illustration F
Operation
1. Plug the mains plug into a mains socket.
2. Switch the device on with the ON/OFF switch.
10
3. To shorten the suction time, raise the pressure hose
approx. 1 m.
Illustration I
4. Wait until the pump simultaneously sucks and deliv-
ers.
CAUTION
Danger due to dry running
Dry running damages the pump.
Do not let the pump run dry!
5. Do not leave the pump unattended during operation.
ATTENTION
Risk of injury. The system is pressurised!
Risk of injury.
(for pressure see chapter "Technical data")
1. Switch off the device at the ON/OFF switch.
2. Pull the mains plug out of the socket.
Care and maintenance
DANGER
Danger of electric shock.
Always switch the device off and disconnect the mains
plug before working on the device.
The device is maintenance-free.
Note
Rinse the pump with clear water after each use when
pumping water with additives.
CAUTION
Risk of injury
Risk of injury from falling device.
When transporting the device, observe the weight of the
device (see chapter Specifications) and secure it ac-
cordingly when transporting it in vehicles.
1
Roll up the cable.
2
Lift and carry the device by the carrying handle.
Transport in vehicles
1
Secure the device against slipping and tipping over.
CAUTION
Risk of injury
Risk of injury from falling device.
When transporting the device, observe the weight of the
device (see technical data) and secure it accordingly
when transporting it in vehicles.
CAUTION
Risk of injury and damage!
The device may tip over on sloping surfaces.
Be aware of the weight of the device during storage.
1. Store the device in a frost-protected place.
Storing the device
1. Depressurise the device by opening the water re-
moval connected to the pressure side (e.g. opening
the garden sprayer).
2. Empty the hoses.
3. Remove suction line and pressure line.
4. Drain the pump via the water drain valve.
Illustration H
English
Ending operation
Rinse
Transport
Manual transport
Storage

Publicidad