Sunea 40 Solar io
1] Press the Down button on the control point to move the motorised product
to the down end limit.
2] Press the Up and my buttons simultaneously until the motorised product
moves up and down.
3] Press the Up or Down button to adjust the tension of the fabric (maximum ½
turn of tube).
4] To confirm the setting, press the my button until the motorised product
moves up and down.
g The "Back impulse" function is set.
NOTICE
- To deactivate the "Back impulse" function, set the angle of the tube to 0°.
- The "Back impulse" function is disabled in factory mode.
2.3.6."Back release" function
NOTICE
This function enables the release of the fabric tension after the complete closing of the motorised product. It is only
accessible for motorised products set in semi-automatic mode.
For safety reasons, this function can only be activated or deactivated by the individual control point in 3 situations:
- After the settings confirmation and before programming the first control point.
- After programming the first control point and during the next 4 cycles.
- After a single power outage and during the next 4 cycles.
To activate or deactivate this function, the procedure is identical:
1] Press the Up button on the control point to move the motorised product to
the upper end limit.
2] Press the my and Down buttons simultaneously until the motorised product
moves up and down.
g The "Back release" function is activated or deactivated.
NOTICE
The "Back release" function is disabled in factory mode.
2.3.7."Closing force" function
NOTICE
This function allows the closing force of the motorised product to be increased or decreased to 3 levels (high/
medium/low). It is only accessible for motorised products set in semi-automatic mode.
Contact the motorised product's manufacturer before using this function to check the compatibility of the
installation.
For safety reasons, this function can only be accessed via the individual control point in 3 situations:
- After the settings confirmation and before programming the first control point.
- After programming the first control point and during the next 4 cycles.
- After a single power outage and during the next 4 cycles.
©
Copyright
2022 SOMFY ACTIVITES SA. All rights reserved.