2.1.4.Installing the drive-tube assembly
CAUTION
The motorised product must not be compressed between the brackets.
1] If necessary, screw the bracket adapter to the drive head (f).
2] Assemble and fix the drive-tube assembly onto the end bracket (g) and onto
the drive bracket (h).
CAUTION
Ensure that the drive-tube assembly is secured onto the end bracket. This operation prevents the tube-drive
assembly from coming out of the end bracket attachment.
2.1.5.Installation of the antenna
For optimal radio reception, it is recommended that the drive antenna extends at
least 10  cm outside of the motorised product housing and at least 1  cm from all
metal surfaces.
To fix the drive antenna in the ideal position, it is recommended to use the Somfy
MOUNTED ANTENNA BRACKET accessory.
CAUTION
• Do not wind or cut the antenna wire. Observe a minimum bending radius (i) of 9 mm.
• Do not protrude the antenna wire from the side of the valances (risk of cutting the antenna)!
2.2.Wiring
WARNING
• To ensure electrical safety, this Class III drive must be powered by a «SELV» voltage source (Safety Extra Low
Voltage).
• Improper using battery pack may cause overheat, fire, explosion, resulting in serious injury or death.
• Do not expose the drive or battery to excessive temperatures.
• There is a risk if terminals of the battery-operated drive or battery being short circuited by metal objects.
PRECAUTION
• Cables routed through a metal wall must be protected and insulated by sleeving or sheathing.
• Secure the cables to prevent any contact with moving parts.
• If the drive is used outdoors and if the power supply cable is of the H05-VVF type or PVC type, run the cable in a
UV-resistant duct, e.g. trunking.
• The drive cable cannot be removed. If it is damaged, return the drive to the After-Sales department.
CAUTION
• The cable between the drive and the battery must not exceed 2.5 m (with wire cross-section min. 0.75 mm²). For
lengths longer than 2.5 m, it is recommended to use an extension cable with a larger cross section.
• Leave the drive power supply cable accessible: the product must be easily replaceable.
• Always make a loop in the power supply cable to prevent water from entering the drive.