5. TECHNICAL SPECIFICATIONS.
TITAN200ACDC
VOLTAGE/FREQUENCY.
MAXIMUM ABSORBED POWER.
MAXIMUM EFFICIENT POWER.
OPEN CIRCUIT VOLTAGE / WELDING VOLTAGE AT 100%.
WELDING REGULATION. (A).
DUTY CYCLE.
Ø MAXIMUM ELECTRODE.
ISOLATION CLASS.
DEGREE OF PROTECTION .
DIMENSIONS.
WEIGHT.
6. INSTALLATION, START UP AND OPERATION.
INSTALLATION
The installation must be made by trained personnel in compliance to the standard IEC 60974-9 and the
current legislation. The input voltage must match the voltage indicated on the technical plate located on
the product. When assembling a plug, make sure it is matching the input voltage and the technical data
stated on the technical plate and that the yellow / green cord is connected to the ground pin. The plug to
which is connected must have the ground connection. The lifting machine should be made through the
handle positioned on top of the product.
Warning: Use all necessary precautions written in the general safety manual before using the machine,
carefully read the risks associated with the process of cutting and plasma welding.
SETTINGS
Set the main switch located on the back side into "ON" position. Set the welding process selector (13) to
TIG AC. Choose 2T with welding mode selection button (12). Adjust the gas flow with regulator. Lower gas
flow would affect the welding quality and cause a porous weld while high gas flow results in bigger
consumption of gas.
The machine is now prepared for work with its preset welding parameters.
Welding parameter selection is done by pressing the buttons (1, 2) until a LED marks the corresponding
position. Once in position adjustment is done by turning the knob (A). Parameter value is displayed on left
display (19). The LEDs on the left of the display show the unit of the selected value.
During welding the display show actual welding current.
Parameters such as: AC balance, 2T - 4T mode, welding process (AC, DC, MMA) and pulsed / continuous
arc are selected or adjusted via special buttons as described in "Front panel description" chapter.
CONTROL PANEL
The machine functions are controlled by the control panel placed on the front panel. The control panel
consists of 3 knobs, selection keys, 3 display and LED's.
MMA
1~ 230V. – 50/60Hz.
4,92 KVA. (I₁
2,21 KW. (I₁
67V. / 22,9V.
72-160
20% 160 A.
4,0mm.
500x455x235mm.
34
TIG
21,4A.)
max.
9,6A.)
eff.
67V. / 13,6V.
89-200
20% 200 A.
3,2mm./CC y 4mm./CA
H
IP21S
10 Kg.