Descargar Imprimir esta página

CEVIK PRO CE-TITAN200ACDC Manual De Instrucciones página 38

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
PROGRAM MEMORY
For saving your personal settings this machine has 9 memory spots at disposal. One memory position
usually marked with numbers from 1-9 on display is always active and any changes made to it are
automatically saved.
To keep the changes press button (24) and program number changes. New program memory spot is active
and available with all changes made to program at previous number already saved automatically.
To recall a program press button (24) until the correct program number shows on display.
To change an already saved program press button (24) until its number shows on display. Now adjust the
welding parameters. To keep these altered settings change the memory spot to next position by pressing
button (24).
THERMAL PROTECTION
Thermal protection is built in machine. If the machine overheats, thermal fuse will prevent further use
and LED (15) will light up. Please wait for machine's temperature to drop to normal. Note the machine
must be left switched on for the fan to keep running and allow faster cooling.
WELDING GUIDELINES
Welding joint forms
TIG DC SETTINGS
Base
Electrode Ø
material
[mm]
[mm]
0,4
1,0 – 1,6
1,0
1,0 – 1,6
1,5
1,0 – 1,6
2,5
1,6 – 2,4
3,0
1,6 – 2,4
4,0
2,4
5,0
2,4 – 3,2
6,0
3,2
Welding
Gas flow [L /
current [A]
min]
5 – 30
4 – 5
10 – 30
5 – 7
50 – 70
6 – 9
70 – 90
6 – 9
90 – 120
7 – 10
120 – 150
10 – 15
120 – 180
10 – 15
150 – 200
10 – 15
38
Bead [mm]
Joint type
1
1,2
1
1,2
1
2
1
2
1 – 2
2,3
2 – 3
4,3
2 – 3
4,3
3 – 4
4,3

Publicidad

loading