Descargar Imprimir esta página

CEVIK PRO CE-TITAN200ACDC Manual De Instrucciones página 39

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
TIG AC SETTINGS
Electrode Ø
Base
[mm]
material
[mm]
1
2
1,5
2
2-3
3
3
4
4
RESET
It is possible to reset the parameters to the factory configuration (factory settings) holding the knob A for
8 second s.
7. MAINTENANCE.
This part of the manual is important for the correct use of welding equipment. It does not contain
specific maintenance instructions as this machine does not require routine maintenance service.
The precautions to be taken into account are the usual ones for any electric welding equipment.
Blow out dust with clean, dry compressed air regularly. The compressed air must not be too
powerful, as it can damage fragile components inside the machine.
If the machine works in high pollution environments, it will need more regular cleaning.
It is recommended to avoid shocks and any form of exposing the machine to falls, sources of
excessive heat, or other situations.
In case of transport and / or storage, the welding equipment should not be exposed to
temperatures outside the range: -10ºC to + 40ºC and air humidity higher than 90%.
Avoid water and steam in the vicinity of the machine. If water enters the machine, DO NOT USE
IT, until you make sure it is completely dry.
In the event of a malfunction or breakdown, do not attempt to repair it unless you have the proper
technical qualifications and tools. Contact one of our technical services, which you will find on our
website www.grupocevik.es.
Maintenance or repair performed by unauthorized technical services will void and terminate the
manufacturer's warranty.
Welding
Additive
current [A]
material [mm]
40 – 60
1,6
50 – 80
1,6 – 2,0
90 – 120
2 – 2,5
150 – 180
2 – 3
180 – 200
3
39
Gas
Joint type
flow [L /
min]
1
7 – 9
2
2
8 – 12
2, 4
10 – 15

Publicidad