Troubleshooting
This troubleshooting guide is for general aid only. For warranty service, contact your
dealer, wholesale distributor, or call 1-800-4KOHLER.
Symptoms
1. No water
flow.
2. The sensor
does not trigger
a flush.
Kohler Co.
Probable Cause
A. The water is not turned
on.
B. Low water supply
pressure.
C. The control stop is
partially or completely
closed.
D. Worn or damaged
piston.
E. Worn or damaged
handle.
F. Loose wire.
G. Pinched or damaged
wire.
H. Disconnected or
damaged electrical
components.
I. Battery is dead or
installed incorrectly.
J. Worn or damaged
solenoid.
A. Obstructed sensor.
B. Disconnected or
damaged electrical
components.
C. Low battery.
Recommended Action
A. Confirm that the water supply
is turned on.
B. Confirm that water pressure
and flow meet the minimum
requirements. Refer to the
"Roughing-In" section.
C. Fully open the control stop.
D. Replace the piston.
E. Lubricate the handle seals with
silicone grease. Replace if
necessary.
F. Check the connections
between the sensor, solenoid,
and battery.
G. Check the wires for damage.
Reroute or replace as
necessary.
H. Disconnect and reconnect the
electrical components. Replace
components as necessary.
I. Confirm that the battery is
installed correctly. Replace if
necessary.
J. Replace the solenoid.
A. Remove objects from in front
of the sensor.
B. Disconnect and reconnect the
electrical components. Replace
components as necessary.
C. Replace the battery.
13
1339618-2-D

Publicidad