Installation instructions
Installing the water line
RISK OF ELECTRIC SHOCK AND DAMAGE TO THE AP-
PLIANCE!
DISCONNECT THE APPLIANCE FROM THE POWER
SOURCE BEFORE PERFORMING ANY WORK ON THE
WATER CONNECTION.
ONLY A QUALIFIED INSTALLATION TECHNICIAN
SHOULD CONNECT THE APPLIANCE TO THE WATER
SUPPLY IN ACCORDANCE WITH PLUMBING AND REL-
EVANT WATER UTILITY COMPANY REGULATIONS.
Connect the appliance to a drinking water line only.
Minimum pressure: 0.17 MPa (1.72 bar, 24.95 PSI)
Maximum pressure: 0.82 MPa (8.25 bar, 119.66 PSI)
Pressure over 0.82 MPa (8.25 bar, 119.66 PSI): install a pres-
sure limiter between drinking water connection and hose set.
Connecting the water line
Most homes are equipped with water line installation parts. If
yours is not or needs replacing, water line installation kits are
available (part number 00646836) or from a hardware store/
dealer.
1. Shut off the main water supply line.
2. Install a shut-off valve and water line 1/4" x 1/4" compression
thread (UNS 7/16-24), accessible with product in place. Re-
fer to local code and instructions with water line installation
kit (not included).
3. Connect the newly installed water supply line (C) to the re-
frigerator water inlet connector (B), tighten using a proper
tool.
Replacing the light bulb
Any replacement or maintenance of the LED lamps should be
made by the manufacturer, its service agent or similar qualified
person.
20
The water should be connected by a competent plumber ac-
cording to the local regulations of the water supply company.
A cold water connection is necessary to operate the ice maker.
The water pressure must be between 0.17 MPa (1.72 bar,
24.95 PSI) and 0.82 MPa (8.25 bar, 119.66 PSI). The installa-
tion must comply with local plumbing regulations.
A separate shut-off valve should be installed in the cold water
inlet.
The shut-off valve should not be located behind the appliance.
It is recommended to mount it directly next to the appliance or
at another place that is easily accessible.
When installing the water connection, pay attention to the per-
missible installation area for the water line.
For connection to the drinking water line, use water pipes that
are suitable for drinking water. Observe national regulations
and the connection conditions of the local water supply compa-
nies.
4. Gently tug on the supply waterline to ensure a proper fit and
risk of damage when pulling or pushing the unit for cleaning.
5. Turn main water back on and check for leaks.
A
B