J6 Expansion Connector; J8 Programmer Connector For Receiver; Display; Status Code - BFT PERSEO-CBE Instrucciones De Uso Y De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
J6
6.5
EXPANSION CONNECTOR
B EBA
RS 485
LINK

7. DISPLAY

At power-on the display shows the board type "", then the FW release X.Y.Z, then the type of bollard (see table on chapter cap. 5),
and fi nally the status or error code.
The status (initial ) or error code is always displayed except in programming menu or when a blocking error is present.
The status code is shown on the fi rst 2 digits.
: Idle
: Opening

: Opening limit switch reached
: Stop activated during opening
: Closing

: Closing limit switch reached
: Stop activated during closing
A standard cycle, without errors, is always 2
On the third digit and dot, additional information is shown:
Display
STATUS
UPS active, mains voltage failure
STOP signal active
"Termon" active
Photocell engaged
Control unit
J8
6.6

7.1 STATUS CODE

: Stop due to photocell triggering

: Opening after photocell triggering
: Pause after photocell triggering
Hydraulic bollards only:
: Stop due to a detected obstacle

: Opening after a detected obstacle
: Pause after obstacle detection
: Maximum working time in opening reached

: Maximum working time in closing reached
->
->
3 when opening, 5
- 28 -
PROGRAMMER CONNECTOR
FOR RECEIVER
6 when closing

Publicidad

Tabla de contenido
loading

Tabla de contenido