The following table gives the 1st level functions and the adjustable parameters.
= DEFAULT value set in factory.
Par
Function
Selects the functioning logic.

(see notes after the table)
Close input confi guration (see

notes after the table)

Photocells
Obstacle detection

(for hydraulic bollards only)

Opening-warning time

Closing-warning time

Bollard lights

Pause time (in seconds)

Buzzer
Preset controlling entrance

confi guration
Resetting default parameters.

(see notes after the table)

Exiting the menu/saving
Description of level 1 parameters

·
: Functioning logic
- Hold-to-run: Close function active for as long as inputs are active. Open function activated by activating and releasing input. The
start command opens once and closes once.
- Semi automatic: The automation works with jog commands, without automatic reclosing. Hence, when fully open, to control closing
you need to act on the start or close command respectively.
- Automatic: The automation works in jogs. When the opening manoeuvre is completed in the standard cycle, automatic reclosing is
activated after the pause time set (parameter ).
Control unit
8.2
PROGRAMMING
1st LEVEL
= parameter value set during installation: should be fi lled if
DEFAULT value is modifi ed.
Settable data
: Hold-to-run
: Semi automatic
: Automatic
: Standard close input
: Close-when-released input
: The close command acts as a close-when-released and safety function.
: During, it reopens and waits for the photo cell free commands closing.
: When closing it reopens; closes after 1'' when the photocell is free
: When closing it reopens; closes after 5'' when the photocell is free
: Disabled
: When closing it stops and waits for commands
: When closing it reopens and waits for commands
: When closing it reopens, then closes after 5 seconds


: Cover lights fl ashing during movement, fi xed on when the bollard is
opened and closed
: Cover lights fl ashing during movement and with bollard open, fi xed on
when the bollard is closed
: Cover lights always fl ashing
: Cover lights fl ashing during movement and with bollard closed, fi xed
on when the bollard is open
-
: Buzzer off
: Buzzer on during movement
: none
: Confi guration of installation type A parameter (see chapter 13.1)
: Confi guration of installation type B parameter (see chapter 13.2)
: Confi guration of installation type C parameter (see chapter 13.3)
: Confi guration of installation type D parameter (see chapter 13.4)
: No resetting
: Resetting the default parameters
: Same as , except for "COM" parameters that are not reset
Pressing the "F" key exits the programming menu and changes are saved