Technical Specifications; Control Panel Dimensions; Installation Safety; Preliminary Operations - BFT PERSEO-CBE Instrucciones De Uso Y De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

3. TECHNICAL SPECIFICATIONS

- Power supply:
- Motor output:
- Flashing light/traffi c light:
- Accessory output:
-Operating ambient temperature

4. INSTALLATION SAFETY

In order to reach the level of safety required by current regulations, read the following prescriptions carefully.
1) Make all connections in the terminal block after carefully reading the instructions given in this manual and observing the general
rules and technical standards governing electrical systems.
2) Upstream from the installation, fi t an omnipole miniature circuit breaker with a contact gap of at least 3 mm.
3) If there isn't one already, install a residual current device with a threshold of 30 mA.
4) Check the eff ectiveness of the grounding system and connect to it all the parts of the automation fi tted with a terminal or grounding
cable.
5) Fit at least one external warning device, such as a traffi c light or fl ashing light, along with a warning or danger sign.
6) Fit all the safety devices required by the type of installation, taking into consideration the risks it can cause.
7) Separate the power lines (min. sect. 1.5 mm
5. PRELIMINARY OPERATION
- Before sending a command to the automation, make sure to have selected correctly the type of bollard as follows:
Bollard selection
- Hold down buttons F and + for 5 seconds to select the connected bollard.
- Select the type of bollard using the buttons +/-.
- Press F and + to confi rm.

PILLAR B 275/600

PILLAR B 275/800 - XPASS B 275/800C

PILLAR B 275/600.6C SD

PILLAR B 275/800.6C SD - XPASS B 275/800C SD

XPASS B 1200C

STOPPY MBB 219-500.C

STOPPY MBB 219-700.C
- Select network frequency through Ht parameter. (see 3rd level programming).
- (Hydraulic bollards only) Select the pressure switch type with the parameter  (see 3rd level programming).
- Check the connection method for simultaneous operation, if controlling multiple deterrent devices simultaneously (see paragraph 10).

6. INPUT AND OUTPUT FUNCTIONALITY AND CONNECTIONS

L N E
230Vac +-10%, 50/60Hz
230Vac; 13A max
230Vac; 40W max
24Vac; 1A max
-25° +60° C

3.1 CONTROL PANEL DIMENSIONS

2
) from the low-voltage signal lines (min. sect. 0.5 mm
J2
6.1
POWER TERMINAL BLOCK
LINE
230V
230V 50/60Hz power supply with varistor internal protection and 5A T (5x20) plus 16A T (6.3x32) fuses.
Connect the phase and neutral as shown on the screen printing. Use a cable type H07RN-F 2x1.5+E min.
Connect the yellow/green wire of the power supply mains to the earth terminal of the appliance.
Control unit
-Operating ambient humidity
-Protection degree
-Storage ambient temperature
BOLLARD TABLE

EASY Ø115-500 - STOPPY B 115/500

EASY Ø200-700 - STOPPY B 200/700

NOT AVAILABLE

NOT AVAILABLE

NOT AVAILABLE

NOT AVAILABLE
- 25 -
up to 95%
non condensing
IP55
-25° +60° C
2
) in the ducts.

STOPPY Ø210-500

STOPPY Ø210-700

NOT AVAILABLE

NOT AVAILABLE

NOT AVAILABLE
EN

Publicidad

Tabla de contenido
loading

Tabla de contenido