Installation D Controlled Entry And Automatic Exit - BFT PERSEO-CBE Instrucciones De Uso Y De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EN
13.4
This solution is recommended when you want to enter a reserved area in both directions. Entry is by means of a command while exiting is
automatic.
ENTRY
EXIT
Loops S1 and S2 also have a safety function in that they will not let the bollard to move all the time if the vehicle is over S1 or S2.
RECOMMENDED
DIMENSIONS
- Connect the contact of loop S1 receiver to PDM input.
- Connect the N.O. contact of the S2 loop receiver to OPEN
input.
- The dimensional values given are approximate.
We suggest installing the "RME 2" metal mass detector.
*
Control unit
INSTALLATION D
CONTROLLED ENTRY AND AUTOMATIC EXIT
PARAMETER
DATA










- 40 -
The vehicle approaches
the reserved area.
When the vehicle is over loop S1 the
bollard will go down only after a com-
mand (ex.: remote control).
If the device is rising and the user
wants to lower it again, the vehicle
must be over loop S1 and the com-
mand must be repeated.
When the vehicle leaves loop S2 the
bollard will rise automatically after an
adjustable pause time.
The vehicle approaches the reserved
area, when it is over the loop S2, the
bollard goes down.
When the vehicle leaves
loop S1 the device will
rise automatically after
an adjustable pause time.
DESCRIPTION
Functioning logic: Automatic
Special function
Radio channel 1: Open
Command during pause is OFF
Close standard

Publicidad

Tabla de contenido
loading

Tabla de contenido