ERROR CODE CHART
LED READING
The Signal wire is loose
- - - / 888 / EEP
Communication failed
Water temperature is below 0°C (32°F)
or exceeds 50°C (122°F)
F0
Temperature sensor failure
F1 immediately shows after pressing FILTER,
HEATING or UVC
F1 shows 15s after pressing FILTER, HEATING
F1
or UVC
PROBLEM
Power socket failure
PRCD is off
NO DISPLAY ON
THE CONTROL
Press the Reset button,
PANEL
the controller is not
PRCD broken
Spa in&outlet connection not
securely tight
SPA LEAKING
Drainage valve is not closed
completely
Temperature set too low
Dirty filter cartridge
The water level is not at the
NOT HEATING
minimum water line
PROPERLY
Heater failure
The filter pump DOES NOT
WORK
Water has been used for a long
period of time
WATER NOT
Insufficient filteration time
CLEAN
Dirty filter cartridge
Improper water maintenance
Auto-off 10 minutes
Internal parts damaged
NO BUBBLE
One-way valve broken
Filter cartridge clogged by dirt
FILTER PUMP
or other objects
DOES NOT WORK
Filter system failure
Water level is below the
minimum water line
OZONATOR
Internal parts damaged
FAILURE
Filter pump does not work
Water level is not at the
JET FUNCTION
minimum water line
FAILURE
Water inlet blocked
(without
icon)
Filter pump does not work
Low water or ambient
JET FUNCTION
temperature
FAILURE
Protection system to sensitive
(with
icon)
TROUBLESHOOTING
CAUSE
CAUSE
Change a socket or repair the socket before use
Reset the PRCD by following the PRCD Testing section
Contact local MSpa Service Center
Contact local MSpa Service Center
Tighten the in&outlet connection
Close the drainage valve. Contact the MSpa Service Center,
if the spa is still leaking
Set a higher temperature
Clean or replace the filter cartridge
Add more water to the minimum line
Contact local MSpa Service Center
Refer to the "FILTER PUMP DOES NOT WORK" section
Change the water
Extend the filtration time
Clean or replace the filter cartridge in time
Refer to the chemical manufacturer's instructions
Wait for 10 minutes and turn on the Bubble button again
Contact local MSpa Service Center
Contact local MSpa Service Center
Clean or replace the filter cartridge
Contact local MSpa Service Center
Add water above the minimum line
Contact local MSpa Service Center
Refer to the "FILTER PUMP DOES NOT WORK" section
Add more water above the minimum line
Clean the filter pump & jet pump inlets
Refer to "FILTER PUMP DOES NOT WORK" section
Heat the water up to 20°C (68°F)
Make sure the water temperature is above 20°C (68°F). Long press
JET button for 3 seconds to unlock the JET function. If Above
operation doesn't work, keep heating the water and try again later.
Contact local MSpa Service Center
Contact local MSpa Service Center
Change the water
Contact local MSpa Service Center
Clean the parts and tubes that the water
goes through
1. Add more water to the minimum line
2. Clean the parts and tubes that water
goes through
3. Contact local MSpa Service Center