Descargar Imprimir esta página

Frigidaire FAW072A2BIW Manual De Instrucciones página 24

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation of the housing
Step 1: Remove the air conditioner from it's packaging, remove fixing screws
and slide the air conditioner out of it's housing (Refer to Installation
Steps).
Step 2: Prepare the hole in the wall so that the bottom of the housing is well
supported, the top has minimum clearance and the air inlet louvers
have clearance as shown below in options A and B. Holes from the
outside through to the cavity should be sealed. The housing should
slope down towards the rear by about 5mm to allow water formed
during operation to drain.
Step 3: Install the housing into the wall and secure. Ensure the foam seals are
not damaged. Flash, seal or fill gaps around the inside and outside to
provide satisfactory appearance and protection against the weather,
insects and rodents.
Sturdy timber
frame all round unit
Timber framed
wall or partition
Preferred method of installation into a timber
framed wall, partition or window.
Installation of the unit into the housing
Step 1: Slide the unit into the housing until it is firmly against the rear of the
housing. Care is required to ensure the foam sealing strips on the
housing remain in position.
Step 2: Connect the air conditioner to the power and position excess cord
length beneath the air conditioner base.
45
All manuals and user guides at all-guides.com
Flash or seal around external
wall frame or architrave
Drain pan
External support frame at
balance point of air conditioner.
Alternatively, brackets as illustrated
below may be used.
Step 3: Engage the chassis fixing brackets into the bottom housing rail and
secure to the base with the screw provided.
Step 4: Remove the front panel from it's carton and plastic bag and fit as per
the Installation lnstruction.
Step 5: Switch unit on. Check for operation of the unit and check for vibration in
the installation.
Step 6: Fit the drain pan to the housing and run a drain line to a suitable
location if required.
Flash or seal around external
wall frame or architrave
Sturdy
timber frame
Timber framed
wall or partition
Alternative method of installation if external
support cannot be provided.
Installations of the unit into the wall
Air in
Air in
Air in
Air out
100mm
OPTION A
Ensure louvres are
entirely outside the wall
Drain pan
Steadying bracket
(one per side)
Solid timber support
Air out
45° brick cut away
To clear louvres
Wall
Wall
Air in
Air in
100mm
Air out
OPTION B
100mm
46

Publicidad

loading