Descargar Imprimir esta página

DITEC EL16 Manual De Instalación página 15

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 30
9.
AUTOMATIONS IN PARALLEL
To control the automations [DRIVE1] and [DRIVE2] in parallel, set DIP3=ON, do not connect terminal 41
(SAFETY TEST), connect the safeties to terminals 1-6 and 1-8. Refer to the connections indicated in fig. 9.1
with selector switch COMH-COMK or in fig. 9.2 with electronic selector switch COME.
Note: adjust the automatic closing trimmers (TC) and the opening (VA) and closing (VC) speed trimmers in the
same position on both automations so as to obtain the simultaneous opening and closing of the door wings.
DIR
DIR
R2
P1
SAFETY
R
E
21 22
M
O
1 2 3
T
RF VA VC RP
COM
DIP
E
ENABLE
RADAR A
COMH
COMK
SAFETY
R
E
21 22
M
O
1 2 3
T
RF VA VC RP
E
COM
DIP
ENABLE
DIR
SAFETY
R
E
21 22
M
O
RF VA VC RP
T
E
COM
ENABLE
1
2
3
4
5
6
COME
DIR
SAFETY
R
E
21 22
M
O
T
RF VA VC RP
COM
E
ENABLE
P2
R1
CELA
24 V
+ -
OPEN
on
1 A B
RADAR B
24 V
24 V
+ -
+ -
OPEN
on
1 A B
R2
P2
P1
R1
CELA
24 V
+ -
OPEN
on
1 A B
1 2 3
DIP
RADAR A
RADAR B
24 V
24 V
+ -
+ -
OPEN
on
1 A B
1 2 3
DIP
15
EL16 DRIVE2
DIP
on
off
1 2 3
1 G141
DIR
EL16 DRIVE1
DIP
on
off
1 2 3
1 G141
DIR
EL16 DRIVE2
DIP
on
off
1 2 3
1 G141
DIR
EL16 DRIVE1
DIP
on
off
1 2 3
1 G141
DIR
EL16 - IP1895
GB
Fig. 9.1
Fig. 9.2

Publicidad

loading