9.
AUTOMATIONS IN PARALLEL
To control the automations [DRIVE1] and [DRIVE2] in parallel, set DIP3=ON, do not connect terminal 41
(SAFETY TEST), connect the safeties to terminals 1-6 and 1-8. Refer to the connections indicated in fig. 9.1
with selector switch COMH-COMK or in fig. 9.2 with electronic selector switch COME.
Note: adjust the automatic closing trimmers (TC) and the opening (VA) and closing (VC) speed trimmers in the
same position on both automations so as to obtain the simultaneous opening and closing of the door wings.