2.3 Outputs and accessories
GB
Output
1
+
0
-
1
+
GP
-
BAT
BL
COM
DIR
OPEN
OPENING
SETTINGS RESET
2.4 DIR connection
Remove the jumper [J] on the control panel connector and insert the DIR card connector as illustrated in fig. 1.
Connect the DIR connector to the control panel by means of the supplied wiring.
Output
OPEN
OPENING
SAFETY
REVERSAL
SAFETY CONTACT
REMOTE
COM
ENABLE
EL16 - IP1895
Value
Accessories power supply. External accessories power supply output.
24 V= / 0,5 A (max)
General Purpose. See hardware key instructions.
24 V= / 0,1 A
The control panel connects the battery and keeps it charged only when there is
mains power; it is used as a buffer battery or when there is no mains power and
disconnects after 30 seconds when the voltage drops below 22 V.
2x12 V / 2 Ah
To charge the batteries, connect the mains power and the batteries at least 30
seconds before starting the system. The power supply and the batteries must
be disconnected in order to switch off the control panel.
Warning: the control panel must be connected to the batteries at all times.
24 V= / 1 A
Blocking device. Blocking device power supply output.
Allows the connection of possible command for distances under 4,5 m.
Allows the connection to the DIR commands branch card.
The opening operation is activated with a brief press.
Keep the OPEN button pressed (for 4 s), until the IN LED starts to flash. To
confirm the operation, press the OPEN button again for 2 seconds within 4
seconds.
The SETTINGS RESET annuls all the remote software settings made via
DMCS, TEL2, COME. After SETTINGS RESET it is possible to adjust the con-
trol panel directly.
Function
Allows an opening control card to be introduced (e.g.: LAN7S, LAN4S, BIXLR22 and
LAB9).
- With the OPEN card introduced, make a jumper across 1-A-B.
- With the OPEN card introduced along with the COMH-K selector, connect terminals 1-
A-B of the DIR card to the related terminals of the COMH-K selector.
Allows the introduction of a safety card (e.g. 0CEL1S).
The jumper needs to be removed in order to introduce the safety card.
The SAFETY command has the same function as command 41-8.
Allows the connection, by means of shielded cable, of possible control apparatus, Personal
Computer or other control panels.
Allows the connection of possible command for distances under 50 m.
A TELRS can be introduced onto the DIR and connected to the COM terminal by means of
the supplied cable. It is therefore possible to connect a PASM24 to the TELRS connector.
To adjust the trimmer and the dip switches on the control panel and DIR card, press the
ENABLE button for 3 seconds with the automation on and the door motionless.
In this way the local setting of the trimmers and dip switches override the previous remote
settings obtained by the DMCS SETTINGS RESET (by means of the OPEN button as
indicated in paragraph 2.3) of TEL2.
Attention: the subsequent individual remote selections and/or adjustments made with the
DMCS and/or TEL2 override the local settings made on the control panel and DIR card.
Description
Description
10