3. INSTALLATION
3.1 Internal unit position
Do not install the internal unit in the following areas:
!
-
areas subject to direct exposure to sunlight;
-
close to heat sources;
-
in damp areas or areas where there is probable contact with water;
-
in areas with greasy vapour or steam
-
in areas subject to electromagnetic interference.
Make sure of the following:
!
-
the wall where the unit is to be installed must have a suitable structure or and load-bearing
capacity;
-
the area of the wall in question does not contain pipes or wiring;
-
the wall is perfectly flat;
-
the minimum installation distances stated in the manual are to be respected.
Failure to abide by the above could adversely affect air circulation into and out of the unit.
3.2 Installation method
The following description of the different assembly stages and the relevant drawings refer to a
version of the machine with left-hand fittings.
Machine assembly operations when the fitting is on the right-hand side are the same but the
images are to be considered the other way around. For successful installation and optimum
performance, follow the instructions in this manual with care. Failure to apply the relevant re-
gulations, which can lead to malfunctions in the equipment will exonerate IRSAP from all forms
of warranty and liability for damage caused to people, animals or property.
3.3 Minimum installation distances
The figures show the minimum assembly
distances for radiators from walls and furniture
in the room.
min. 20 mm
40
min. 20 mm 107
min. 200 mm
min. 20 mm
107