- Fasten the screws, using a spirit level to adjust as needed
- Connect the supply and return pipes to the system.
Use a suitable insulation to prevent the
formation of condensation
- Connect the condensation drainage pipe,
(for more information, see the specific chapter).
ELECTRONIC CONNECTION
Open the wiring box and connect the power to the terminal strip
- Open the screw closing the wiring box
- Connect the wires L, N and T as shown in the diagram
- Close the wiring box
- Use the cable grips provided to secure the wires leaving the box
CIRCULATOR CONTROL
The radiator can switch on the heating system circulator when it is needed and switch it off
when it is not required, by closing a clean contact.
To enable consent to switching on the system circulator, it is necessary:
- Create a bridge between C1 and C2 as shown in the figure (1 with 3, 2 with 4)
- Connect the 2 wires from the circulator control to the contacts of terminals 1 and 2
48
- Position the internal unit on the wall level
with the bores
Ø16
4x
N
L
T
L N