5.11 BUTTON LOCK
Button
Function
Hold down the + and - buttons for 3 seconds to lock the the +, - and stand-by buttons.
This is confirmed by the letters bL on the display.
Set-point variation and switching off are thus inhibited by the user. Repeating the
sequence will release the buttons.
5.12 MINIMUM BRIGHTNESS REDUCTION
After a period of 20 seconds from the last action, the lighting in the panel is dimmed to increase
comfort during the night and the display shows the room temperature.
5.13 DEACTIVATION
Button
Function
Hold down the ON standby button for approx. 2 seconds. The lack of any lit signal on the
display identifies the "stand-by" status (no function).
The control guarantees anti-freeze safety, even when it is set to stand-by.
5.14 SWITCHING OFF FOR LONG PERIODS
When switching off the system for seasonal reasons or holidays, proceed as follows:
- Deactivate the appliance
- Set the main switch for the system to Off.
The anti-freeze function is not active.
!
5.15 ERROR SIGNALS
Error
Ambient temperature probe failure (AIR).
Problem with the ventilator motor (for example, jamming due to foreign bodies, rotation sensor failure).
Water temperature probe failure (H2). In this case, make sure that the probe fitted is a 10 kΩ.
If one of the 2 symbols flashes, this means that the water temperature (hot or cold) is not met and this
will cause the ventilator to stop.
62
Display
BL
Display
SPENTO
Display
E1
!
E2
!
E3
!