______________________________________________________________
3.
SPECIFICATIONS
Measuring ranges
Scaling factor
Output sensitivity
Accuracy (45-65Hz)
Noise
Output Connector
Power Supply
Battery Life (typ.)
external
Connector
Output load
Frequency range
Phase angle error
Position sensitivity
External field
Temperature coeff.
Low battery
Overload
_______________________________________________________________
METRAFLEX
300MXBL
3A
2
0.5V/A
±1% of rdg.
±0.1A
40mArms 80mArms 400mArms
Hypertronics connector
Battery
2x AA MN1500 LR6 Alkaline
80 hrs (M'FLEX 300MXBL)
2...3VDC/max. 100mA
Barrel plug socket 5,5/2,1mm
minus at center pin
≥100 kΩ for specified accuracy
25 Hz to 50 kHz (-10% attenuation)
<±1° (45-65Hz)
±2.5% of reading
±0.5% of range with cable >200mm
(8") from the probe
±0.15% / °K
Indicated by an orange LED
Indicated by a red LED
30A
300A
20
200
50mV/A
5mV/A
±1% of rdg.
±0.5A
7