EN - ENGLISH (translated from the original manual)
1 – INTRODUCTION: TECHNICAL FEATURES OF THE ELECTRONIC
SYSTEM
All the parameters of the Triflex Connect Dupla control unit can be set through
the PROG programmer (programming tool) in three languages (Portuguese,
English or Spanish). It can be used on all models of PPA operators with in-
duction motors.
It is endowed with an EEProm
memory that stores all codes of the remote
1
controls in an encrypted form, as well as the control unit operation param-
eters, such as the deceleration zone, pause time etc. The unit control is also
compatible to Rolling Code Remote Controls with PPA's own protocol.
The system can be activated by remote control through a bult-in radiofre-
quence receiver, a loose receiver or any other device with a NO (Normally
Open) contact as, for example, a pushbutton.
2 – CONTROL UNIT
2.1 – ELECTRICAL CONNECTIONS
The General Wiring Diagram can be seen below.
2.2 – SYSTEM POWER SUPPLY
The operator must be connected to the power grid through the L and N inputs
on the power terminal block, 100 V - 230 V connector, according to figure 1.
Warning: The operator is dual voltage (auto range); one has only to plug it into
a 100 V - 230 V power supply; the utility frequency can be either 60Hz or 50Hz.
2.3 – INDUCTION MOTOR CONNECTION
The three cables on the induction motor must be connected to the "MOTOR1"
and "MOTOR2" terminal blocks. THERE IS NO CORRECT COLOR SEQUENCE
.
2
Motor 2 is factory set as the 'delay' motor.
1 EEPROM (from Electrically-Erasable Programmable Read-Only Memory) is a
non-volatile storing chip used in computers and other electronic devices.
2 Refer to item 3.1 – FIRST ACTIVATION AFTER INSTALLATION (ACQUIRING /
SELF-LEARNING).
17