4.3 – ADJUSTING PARAMETERS THROUGH THE 'TACTLED SYSTEM'
The control unit is also endowed with quick access functions through its but-
tons. When the 'PROG' jumper is closed, one can press the button corre-
sponding to the desired function in order to set it. In order to increase the
values, one can press the button again until one reaches the desired level.
There are eight levels; the LEDs from N1 up to N8 indicate the respective level.
If one wants to decrease the value, one can press the same button until the
LEDs go off and start from the first again.
In order to change another parameter, press the desired button and repeat
the procedure.
In order to save the changes, one can open the 'PROG' jumper. The gate can
now operate normally.
Programming Functions Table:
Button
Limit switch travel speed
Speed near the stoppers.
It has an interval of 5 Hz, from 10Hz up to 50Hz.
"VFC"
Note: The acquiring (memorization, self-learning) speed is the
same as the limit switch, since it is larger than 20 Hz; in case it
is smaller, the control board automatically uses 20 Hz during
the acquiring procedure.
Function for adding and erasing remote controls (TX)
1 – Adding: In order to add a remote control, press a button
of the desired remote control; then, observe that the 'SN' LED
quickly flashes if it is receiving the signal. Press the 'TX' button
again to add the control. Observe that the 'SN' LED remains
"TX"
lit when it receives a signal already added to the control unit.
2 – Erasing: In order to erase the remote controls added to
the memory, press the 'TX' button for 10 seconds; observe that
the 'SN' LED flashes every one second. After the 10-second
interval has elapsed, the 'SN' LED stops timing; at this
moment, all added remote controls have been erased.
Speed
"VEL"
Adjusts the opening / closing speed of the gate.
Note: It has an interval of 10Hz, from 60Hz up to 140Hz.
Semi-automatic function/Pause time on automatic
mode.
"PAUSA"
It has an interval of 30 seconds, from 0 second up to 180
seconds. When '0' is chosen, the operator becomes semi-
automatic.
Function Description
23