The gate operator can operate only with ENCODER or ENCODER plus
REED, but cannot operate with REED only. When the gate is closing
during the self-learning, only a photocell command can reverse the
gate movement.
The automatic gate is now ready to operate.
Note: If the swing gate is endowed with a rabbet (metal strip to hold one of
the leaves), one must enable a motor delay through PROG. The delay will be
enabled on Motor 2.
3.2 – FROM THE SECOND ACTIVATION ON, WHEN THE CONTROL UNIT IS
After the previous operation, the gate will not need to acquire (memorize) the
travel again. It will simply and slowly close after a command, until it leans on
the closing stopper; the motor will turn itself off after a couple seconds. The
automatic gate is now ready to operate.
In case the photocell beam is obstructed or the control unit receives a com-
mand during this first closing movement, the reference point to be sought will
be the opening one, in order to accelerate the acquiring of a known point of
the gate's travel.
IMPORTANT: In Hybrid mode, i.e., REED plus ENCODER, if the gate is
located in one of the REEDs, the gate will start with full speed, without
needing to acquire the gate's travel (path).
It is important to install fixed opening and closing stoppers on the
gate that will be automated.
4 – PROGRAMMING THE INVERTER PARAMETERS
When the 'TST' DIP switch is turned on, the control unit enters in an operation
mode which allows one to place the operator in a specific point of its travel
(path) in order to set the limit switch limits or even to check the mechanical
part.
In this operation mode, whenever one presses the 'VFC' button, the motor 1 is
activated clockwise while the button is being pressed; once it is released, the
motor turns itself off, and when the 'TX' button is pressed, the motor operates
counteclockwise. The 'VEL' and 'PAUSA' buttons have the same functions, re-
spectively, to the motor 2.
22
WARNING
DISCONNECTED FROM THE POWER SUPPLY
4.1 – 'TST' FUNCTION
CAUTION