Stop on opening
Lock pulse on
closing
Motor starting
speed
Stoppers' gap
Operator model
Photocell Input
ports calibration
Language
Slave delay
28
This function is usually enabled in gated
communities, in order to avoid that the gate stops
during the opening maneuver, due to commands
from remote controls from several residents at the
same time.
This function enables the lock during a closing
maneuver in order to retract its pin (for gates which
do not have the mechanical device that pushes the
pin of the electromagnetic lock at the moment).
This function adjusts the first speed applied to
the motor during any beginning of movement;
it usually is lower in order to avoid a peak of
energy consumption on starting and provides
it with increased security in case the encoder is
desconnected or damaged.
Function for systems using 'ReedDigital' only, in
order to avoid that the operator switches itself off
with the gearmotor too pressed against the (opening
and closing) stoppers. It reduces wear and tear of the
pinion and other mechanical components.
Caution: When the system is hybrid (Encoder plus
magnetic reed), this function is automatically set to
zero, since the magnetic reed determines where the
gate stops.
Function which applies initial values to the
parameters closer to the operator being used.
This function calibrates the input ports of the
photocells. To do so, one must connect all protection
devices to the 'FA' and 'FF' input ports, keep all
devices level (aligned / without obstruction) and
press the button '+'.
PROG's Language selection, available in Portuguese,
English and Spanish.
Slave gearmotor delay (Motor 2). The time set here
is used to wait to move the motor 2. During closing
it is inverted, i.e., motor 2 closes first and then it waits
to start closing motor 1.