Symbols on the machine
Do not suck in any ignition
sources! Suitable for suction
of combustible dusts of the
dust explosion classes in
Zone 22.
Flat fold filter
Order No.
Dust disposal bag
Order No.
Safety filter bag
Order No.
be tightly sealed with the connection bush-
ing.
Safety instructions
Danger
When the outgoing air is carried back
–
into the room, a sufficient ventilation
rate L in the room must be ensured. To
comply with the required limit values the
carried back volume flow must be 50%
6.904-364.0
6.907-347.0
6.904-420.0
When using the dis-
posal bag, the lower
suction nozzle must
be tightly sealed.
When using the
safety filter bag, the
upper suction noz-
zle must be tightly
sealed.
Two suction hoses
may not be con-
nected to the vacu-
um cleaner at the
same time. One
suction nozzle must
of the fresh air volume flow (room vol-
ume V
x ventilation rate L
R
mum. Without a specific ventilation
system the following applies: L
Only persons trained in the use of the
–
machine and the handling of substanc-
es for which the machine is to be used
including training in the safe disposal of
the sucked-in material may use the ma-
chine.
This appliance contains harmful dust.
–
Evacuation and maintenance work, in-
cluding the disposal of the dust collec-
tion containers, may only be performed
by specialists who wear the appropriate
protective equipment.
Do not use the appliance without the
–
complete filtering system.
Please follow the safety regulations ap-
–
plicable to the materials that are to be
treated.
The accessories approved by the man-
–
ufacturer are electrically conductive. Do
not use any other accessories!
Vacuum only using all the filter ele-
–
ments; otherwise, the suction motor can
get damaged and this can be hazard-
ous to health on account of increased
release of fine dust particles!
Please observe the safety regulations
–
applicable to the materials to be vacu-
umed up. During proper/improper oper-
ation parts of the appliance can reach
temperatures of up to 95 °C.
You are not allowed to use an extension
–
cable.
In case of emergency (e.g. in case of a
short or other electrical errors), switch off
the appliance and pull the mains plug.
– 3
EN
) at maxi-
W
In Emergency
=1h
.
–1
W
21