Descargar Imprimir esta página

Steinberg Systems SBS-PT-200S Manual De Instrucciones página 50

Ocultar thumbs Ver también para SBS-PT-200S:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 180
3. There is a mounting plate on the back of the display. There are two holes in the
mounting plate for screws.
4. Put the screws through the holes in the mounting plate.
5. Position the mounting plate at the target installation location of the display.
6. Screw the screws into the wall studs.
7. Use the pressure screws on both sides of the display to secure it at the desired
tilt angle.
CALIBRATION:
A. SBS-PT-200S; SBS-PT-100S; SBS-PT-200SB; SBS-PT-100SB1
• Switch off the unit using the "ON/OFF" button
• Hold the "ZERO" button for a few seconds, then press the "ON/OFF" button. The
unit will turn on displaying "X00.00". The letter "X" will start flashing.
• Select the calibration unit (kg; Ib) by pressing the "UNIT" button to the effect.
• A flashing symbol in the displayed message indicates that the digit can be changed.
Use the "HOLD" button to select the digit to be changed, and use the "ZERO" button
to increase the flashing value.
• Press the TARE button. The display will indicate the number of measurements
taken so far.
• Press the UNIT button. The display will indicate the set calibration value.
• Place the weight with the displayed weight on the weighing platform.
• After the reading has stabilized, press the "UNIT" button.
• The display "----" indicates that the calibration is complete. Remove the weight
from the platform.
• Switch off the unit using the "ON/OFF" button
B. SBS-PT-200SK; SBS-PT-100SK:
• When the scale is off, hold the "UNIT" button for a few seconds, then press the
"ON/OFF" button. The display will show "CALU=".
• Press the "UNIT" button until the calibration unit (kg; Ib) is selected.
• Press the TARE button. The display will show the message "XXX.XX + (selected
calibration unit)".
• The first symbol in the displayed message will start flashing. This indicates that a
particular digit can be changed. Press the "UNIT" button to select the digit to be
changed, and use the "ZERO" button to increase its value.
• Press the TARE button. The display will indicate "-CAL-".
Press the "UNIT" button twice. The display will indicate the set calibration value.
• Place the weight with the displayed weight on the weighing platform.
• After the reading has stabilized, press the "UNIT" button.

Publicidad

loading