Descargar Imprimir esta página

Steinberg Systems SBS-PT-200S Manual De Instrucciones página 55

Ocultar thumbs Ver también para SBS-PT-200S:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 180
3. To return to normal weighing mode, turn the unit off and then back on with the
"ON/OFF" button.
C. SBS-PT-60SNL; SBS-PT-150SNL:
Level 1:
1. Turn on the unit while holding down the "ZERO" button. When the unit is
started, let go of the "ZERO" button.
2. Press the "TARE" button three times. The unit will go to the list of available
functions to adjust.
3. To adjust the displayed parameter, press the "UNIT" button. The parameters
are adjusted using the "TARE" button.
4. To return to the main settings menu or skip a parameter and move to the next
one, press the "ZERO" button.
Available settings:
DISPLAYED
Corresponding
MESSAGES:
function
A-OFF
Automatic
shutdown
(adjusting the time
after
function will be
activated)
b.L
Backlight
UNIT
Weighing
(selecting
weighing unit in
this
responsible for its
appearance when
the "TARE" button
is pressed during
measurement)
Function adjustment options
Automatic shutdown will occur after:
• 120,
• 180,
which
the
• 300 seconds of inactivity,
• OFF (function disabled)
• ON – on
• OFF – off
• STB – on if there is an animal/object on the
platform; turns off automatically 12 seconds
after the reading is stabilized
• AUTO – on if there is an animal/object on the
platform; off if the reading is 0
unit
• ON kg or OFF kg – weighing in kilograms
the
on/off
• ON LB or OFF LB – weighing in pounds on/off
menu
is
• ON oz or OFF oz – weighing in ounces on/off

Publicidad

loading