Operating Manual – SolarMax 2500 Accu
1
This operating manual contains important information that will help you install your SolarMax 2500 Accu fountain pump. Please read the operating manual carefully before installing
the solar unit and keep the manual somewhere safe..
Delivery contents
y
Technische Daten
Art. No.
Solar module
Nominal power
Nominal voltage
Nominal current
Surge protection class
IP protection class
Temperature range
Pump
Operating voltage
Operating current
Maximum pump capacity (Qmax)
Maximum flow height (Hmax)
Surge protection class
IP protection class
Operating temperature
Dry running protection
Safety instructions
• The pump is designed to operate with direct current (DC). Never connect the pump to a power supply with alternating current (AC).
• Do not knock the solar module with your hands, tools or other objects. A damaged solar module cannot be repaired and must be disposed of in an environmentally compatible manner.
• Never open the casing of the device or any of its associated parts unless explicitly indicated in the instructions.
• The pump must not be operated without water as this may cause irreparable damage.
• This device is suitable for pumping water with a minimum temperature of 10°C up to a maximum of 40°C.
• The pump not designed for operation in salt water or for pumping drinking water.
• The device may be used by children from the age of 8 upwards and also by people with physical, sensory or mental disabilities or lacking suitable knowledge and experience,
provided they are supervised or have been instructed in the use of the device and understand the resulting hazards. Children must not be allowed to play with the device.
Cleaning and user maintenance must not be carried out by children without supervision.
• If the solar module is set up without the module retainer, care must be taken to ensure adequate stability to prevent damage to the solar module.
• Keep children away from the packaging material and small parts. There is a risk of suffocation!
• The battery box must not be placed in direct sunlight or water.
SolarMax 2500 Accu
13511183
35 W
18 V DC
2025 mA
III
IP65
-30°C to +75°C
18 V DC
900 mA
2,480 l/h
2.1 m
III
IP68
+5°C to +40°C
Yes
1. Solar module
2. Module retainer (pipes, earth spike)
3. Solar pump with 5m connecting lead
4. Extension cable
5. Battery box
6. Extension pipe adapter
7. Extension pipe (4 pcs.) and jet attachments (3 pcs.)
Connecting cable
Battery box
Connecting cable
Surge protection class
IP protection class
Operating temperature
Charging voltage
Nominal power
Output voltage 1
Output voltage 2
Battery
Category
Technology
Connection
Voltage/capacitance
Deep discharge protection
Dimensions (L x H x W)
3
5 m
5 m
III
IP44
-5°C to +40°C
18 V DC
50 W
18 V DC
DC 6 W
Rechargeable lead accumulator
Lead-fleece (absorbent glass mat)
Flat blade connector 4.8 mm
12 V / 12 Ah
Yes
152.4 x 96.5 x 99.1 mm