Operating Manual – SolarMax 2500 Accu
1
Replacing the battery
1. Remove the 6 screws on the bottom of the battery box cover and take off the cover.
2. Pull off the red or brown cable clamp on the positive battery terminal (+) and then the blue cable clamp on the negative battery terminal (-).
3. Take out the old battery and insert the new battery.
4. Attach the blue cable clamp on the negative battery terminal (-) and then the red or brown cable clamp on the positive battery terminal (+).
5. The battery box is now ready for operation again.
TROUBLESHOOTING
Problem
The pump is not running
The system indicator LED is on RED
The pump is running but no water is coming out
2
Warranty
We offer a warranty of two years on workmanship and materials from the date of purchase. To make a claim on the warranty, the original sales receipt must be enclosed. Warranty
repairs may only be carried out by an authorised customer service provider. This warranty does not cover: ordinary wear and tear, alterations, reworking, damage due to negligence,
third parties and applications for which the product has not been designed, partially or completely disassembled products..
Environmental protection
1. Product:
Old electrical equipment should not be disposed of with the household waste. Before disposing of your old equipment at your local recycling centre, remove the
batteries and dispose of them separately from the product! Further information can be obtained from your equipment dealer or waste disposal company.
2. Product:
End-consumers are legally required to return used batteries under the Battery Directive! You can hand in your used batteries free of charge at your local municipal
collection points or anywhere where batteries are sold. Disposal via the household waste is prohibited!!
Conformity declaration
The undersigned company UBBINK GARDEN BV declares on it own responsibility that the device SolarMax 2500 Accu satisfies the requirements of the European Directive 2014/30/EU
(Electromagnetic Compatibility). The following harmonised standards were applied:
EN 61000-6-3:2007+A1:2011
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 61000-6-1:2007
Possible cause
The solar module is not connected
The system switch is on "OFF"
The timer switch is on "ON".
The dry running protection has activated
The battery is worn out
The impeller is stuck
There is not enough sunshine to charge the battery,
The pump outlet or fountain jet is blocked
6
Remedy
Check the electrical connection between the battery box
and the solar module.
Turn the system switch to "ON"
Turn the timer switch to "OFF"
Make sure the pump is fully submerged in water.
Replace the battery
Clean the pump as described under "Cleaning and
maintenance"
wait for the sun to shine so that the battery can recharge
Clean the pump outlet, riser pipes and fountain jet.